What is MEP acoustics?

MEP acoustics is the control of noise and vibration produced by a building's mechanical, electrical and plumbing equipment. It covers the sound travelling down ducts, breaking out of plant rooms, radiating from outdoor units and passing into the structure as vibration.

Equipment-specific pages cover HVAC acoustics, FAHU and AHU noise and generator rooms. Our MEP acoustic contractors install attenuators and isolators.

Mechanical plant is the most common source of noise complaints in finished buildings, and almost always the cheapest to deal with at design stage. As MEP acoustics consultants we take the equipment schedule and layouts from the MEP designer, calculate the noise reaching each occupied room and each boundary, and specify what is needed to meet the target.

HVAC noise control includes duct attenuator selection, air velocity limits, terminal and grille noise checks and plant room wall and door ratings. Vibration isolation is specified for chillers, pumps, fans and pipework, with spring and rubber mounts chosen for each machine. We prepare the noise calculation for chillers, AHUs and generators that consultants and authorities ask for.

Detailed topics have their own pages: HVAC acoustics, FAHU and AHU acoustics and generator room acoustics. The service belongs to our acoustic consultant practice and works hand in hand with our HVAC consultant team. Supply and installation of attenuators, enclosures and isolators is offered by MEP acoustic contracting.

What's included

Duct-borne noise calculations

Fan noise followed through the duct system to each room.

Attenuator selection

Silencer sizes and positions with pressure drop checked.

Plant room breakout

Wall, slab and door ratings to contain equipment noise.

Vibration isolation

Mounts, hangers and inertia bases specified per machine.

Outdoor plant noise

Chiller and condenser noise at neighbours and boundaries.

Commissioning measurements

Noise levels verified once the system is running.

When to call us

You do not need a finished brief. If any of these sounds familiar, let's talk.

  • Occupants can hear the AC, pumps or lifts.
  • Equipment is being selected and you want noise checked first.
  • A reviewer has asked for MEP noise calculations.

How we work

  1. Brief and survey

    We review drawings, visit the site where needed and agree the scope and the standard to design to.

  2. Calculate

    We run the calculations and record the inputs and assumptions so they can be checked.

  3. Design and document

    Drawings, schedules and a clear report, issued for your review.

  4. Support through approval and site

    We answer review comments and stay available while the work is built.

Where we work

  • Offices and fit-outs
  • Residential towers and villas
  • Hotels and restaurants
  • Malls and retail
  • Hospitals and clinics
  • Factories and plant rooms

Trusted by teams across Dubai and the UAE

  • Empower Energy Solutions
  • APT
  • J-Walt
  • Nimsmarts Technical Services
  • Taslleeh Engineering Solutions
  • VICC Venco Imtiaz Construction Co
  • Awqaf Dubai
  • Burj Al Yarmouk Industries
  • BurJuman
  • Care 4 Group of Companies
  • Dubai Airports
  • Dubai Metro
  • Extol International
  • Future Gulf Contracting
  • Mohammed Bin Rashid Space Centre
  • Speed House Group of Companies

What clients say

See our Google reviews

Really good experience with Solve Tech Vision. Their MEP calculation work was accurate, and the team was easy to communicate with.

Wamala Brenda

Professional MEP consultants in Dubai. They understood our requirements quickly and provided clear technical support.

Mithun Kumar A

Very professional engineering team. Good communication, practical advice, and smooth service from start to finish.

Amani Ziane

The team was genuinely helpful and responsive. They handled our engineering requirements professionally and made the whole process easy.

Shoaib Alam Mohammed

MEP Acoustics: questions, answered

How is HVAC noise reduced?

By selecting quieter equipment, keeping air velocities sensible, fitting attenuators and isolating vibration. Which matters most depends on the path the noise takes.

What noise level should an office or bedroom have from building services?

Design targets are normally given as NC or NR ratings, or dBA, and depend on room type. We agree the criterion before calculating.

Can a noisy rooftop chiller be treated after installation?

Usually yes, with screens, enclosures, attenuators or isolation, but options are more limited than at design stage.

What causes noise from MEP systems?

Fans, pumps, chillers, generators and airflow in ducts and pipes create airborne noise and vibration that travels through the structure into occupied spaces.

At what stage should MEP acoustics be checked?

At design stage, when equipment is selected and plant room positions are fixed. Swapping to a quieter fan or adding a silencer on paper costs little; adding it after the ceiling is closed can mean rebuilding ductwork.

Ready to talk about your project?

Call +971 524064300, or send us your drawings and we will reply with next steps.

Call WhatsApp