FAHU and AHU Acoustic Services in Dubai

Fresh air and air handling units are big noise sources. We keep them from disturbing the spaces around them.

Call +971 524064300

Why are AHUs and FAHUs so noisy?

Air handling units house large fans that make noise through the supply and return ducts, through the unit casing into the room around it, and as vibration through the structure. Each path needs its own control: silencers for the ducts, heavier construction for the room and isolators for the fan and pipework.

AHU noise is one part of MEP acoustics; the rest of the air system is covered by HVAC acoustic services. Silencers and isolators are installed by our MEP acoustic contractors.

AHU and FAHU noise tends to show up after handover, when the plant room is above a meeting room or the unit sits next to a bedroom wall. By then the options are limited and expensive.

We review the unit sound data, size the silencers, and design the plant room construction and vibration isolation so noise stays where it belongs. It sits naturally alongside our wider MEP acoustics work.

What's included

Sound power review of AHU/FAHU units

Manufacturer data checked against room and boundary targets.

Discharge and intake silencer design

Attenuation for the air paths to and from the unit.

Casing breakout and plant room walls

Wall and ceiling construction that contains casing noise.

Vibration isolation and flexible connections

Isolation for units, ducts and pipework.

When to call us

You don't need a finished brief. If any of these sounds familiar, let's talk.

  • A plant room sits next to or above occupied space.
  • An installed unit is louder than the design predicted.
  • You're selecting AHUs and want the noise checked first.

How we work

  1. Brief and site review

    We review drawings, how the space is used and your target, and visit the site where it helps.

  2. Measure and model

    We survey existing noise, then model sound levels and reverberation to test the options.

  3. Design and specify

    You get treatment details, specifications and schedules ready for tender and construction.

  4. Review and sign-off

    We check submittals, support your contractor and verify the result on site.

Where we work

  • Commercial buildings
  • Hospitals
  • Hotels
  • Data and technical spaces

Trusted by teams across Dubai and the UAE

  • Empower Energy Solutions
  • APT
  • J-Walt
  • Nimsmarts Technical Services
  • Taslleeh Engineering Solutions
  • VICC Venco Imtiaz Construction Co
  • Awqaf Dubai
  • Burj Al Yarmouk Industries
  • BurJuman
  • Care 4 Group of Companies
  • Dubai Airports
  • Dubai Metro
  • Extol International
  • Future Gulf Contracting
  • Mohammed Bin Rashid Space Centre
  • Speed House Group of Companies

What clients say

See our Google reviews

Really good experience with Solve Tech Vision. Their MEP calculation work was accurate, and the team was easy to communicate with.

Wamala Brenda

Professional MEP consultants in Dubai. They understood our requirements quickly and provided clear technical support.

Mithun Kumar A

Very professional engineering team. Good communication, practical advice, and smooth service from start to finish.

Amani Ziane

The team was genuinely helpful and responsive. They handled our engineering requirements professionally and made the whole process easy.

Shoaib Alam Mohammed

FAHU/AHU Acoustics questions, answered

Can an existing AHU be made quieter?

Usually. Options include adding silencers, lining ducts, isolating the unit and improving the plant room enclosure.

Where does AHU noise travel?

Through supply and return ductwork, through the unit casing into the room around it and as vibration through the structure.

Why is a rooftop FAHU heard in the apartments below?

Mostly through structure-borne vibration, when the unit sits on the slab without proper springs or the inertia is too low, and through casing breakout down unlined ducts or shafts. A survey at night, when background noise is low, usually shows which path dominates.

What information do you need to assess AHU noise?

The manufacturer's sound power data by octave band for the supply, return and casing, the fan duty, duct layouts and the room types served. If the unit is installed, we also measure on site.

Ready to talk about your project?

Call +971 524064300, or send us your drawings and we will reply with next steps.

Call WhatsApp