Fire Fighting Consultant in Dubai
Sprinklers, hose reels and fire pumps designed to the code and proven by hydraulic calculation, not by guesswork.
What does a fire fighting consultant do?
A fire fighting consultant designs the water-based and special systems that control a fire: sprinklers, hose reels, landing valves, hydrants, fire pumps and tanks, and where needed gas or foam suppression. The design is checked against the UAE Fire and Life Safety Code of Practice and the relevant NFPA standards.
Detection is designed by our fire alarm consultants, and our fire fighting contracting team installs and tests the systems we design.
Fire fighting design is the part of a building that everybody hopes never gets used, which is exactly why it has to be right on paper. As a fire fighting consultant in Dubai we classify the hazard of each area, select the system type, and run a sprinkler hydraulic calculation to prove that the most remote sprinklers get the flow and pressure the code requires.
Our fire fighting system design covers wet and dry risers, sprinkler zoning, hose reel and landing valve locations, external hydrants, fire pump room layout, fire water tank sizing and breeching inlets. For server rooms, electrical rooms and kitchens we design clean agent and wet chemical suppression. The fire detection side is handled with our fire alarm consultant so the two systems work as one.
We prepare fire fighting design for Civil Defence approval in Dubai as drawings, schedules and calculations for submission by the project's approved parties, and we respond to review comments. The service sits within our MEP consultant offering next to plumbing design, and installation is available through fire fighting contracting.
What's included
Hazard classification and system selection
The right system for each area, with the reasoning stated.
Sprinkler layout and hydraulic calculation
Head spacing, pipe sizing and remote-area calculations.
Fire pump and tank sizing
Electric, diesel and jockey pump duties and fire water storage.
Risers, hose reels and hydrants
Locations and pipework to code-required coverage.
Special suppression design
Clean agent, CO2 and kitchen hood systems for specific risks.
Review of existing systems
Gap check against current code before a renovation or change of use.
When to call us
You do not need a finished brief. If any of these sounds familiar, let's talk.
- You are changing a layout or use and need to know if the sprinkler design still complies.
- A fire fighting package has been returned with comments.
- You need pump and tank sizing before the plant room layout is frozen.
How we work
Brief and survey
We review drawings, visit the site where needed and agree the scope and the standard to design to.
Calculate
We run the calculations and record the inputs and assumptions so they can be checked.
Design and document
Drawings, schedules and a clear report, issued for your review.
Support through approval and site
We answer review comments and stay available while the work is built.
Where we work
- Villas and residential
- Offices and commercial buildings
- Hotels and hospitality
- Healthcare
- Warehouses and industrial units
- Mixed-use developments
Trusted by teams across Dubai and the UAE
What clients say
See our Google reviewsReally good experience with Solve Tech Vision. Their MEP calculation work was accurate, and the team was easy to communicate with.
Professional MEP consultants in Dubai. They understood our requirements quickly and provided clear technical support.
Very professional engineering team. Good communication, practical advice, and smooth service from start to finish.
The team was genuinely helpful and responsive. They handled our engineering requirements professionally and made the whole process easy.
Fire Fighting Consultant: questions, answered
Which codes do you design to?
The UAE Fire and Life Safety Code of Practice, with NFPA 13, 14 and 20 as the main technical references for sprinklers, standpipes and fire pumps.
Do you submit to Dubai Civil Defence yourselves?
We prepare the design package and support the review. Submission goes through the parties Civil Defence approves for the project; we will tell you at the start who needs to be involved.
What is a hydraulic calculation and why is it needed?
It proves that the most demanding area of the building receives enough water at enough pressure when sprinklers operate. Without it, pipe and pump sizes are assumptions.
Can you redesign sprinklers for a fit-out?
Yes. Partitions and ceilings change coverage, so we re-plan head locations and check the hydraulics against the existing riser.
Which code applies to fire fighting systems in Dubai?
Dubai Civil Defence enforces the UAE Fire and Life Safety Code of Practice, which refers to NFPA standards such as NFPA 13 for sprinklers, NFPA 14 for standpipes and NFPA 20 for fire pumps. Our designs follow the code edition in force at the time of submission.
Related services

Fire Fighting Contracting
Sprinklers, hose reels, hydrants, fire pumps and suppression systems installed and tested.
Read more
MEP Consultant
HVAC, electrical, plumbing and fire fighting design with the calculations to back it up.
Read more
HVAC Consultant
Heat load calculations, duct and pipe sizing and equipment selection.
Read more
Ready to talk about your project?
Call +971 524064300, or send us your drawings and we will reply with next steps.