VFD Contracting and Installation in Dubai

Drives supplied, installed, set up and commissioned on your motors, with the parameters recorded for the day you need them again.

Call +971 524064300

What is included in VFD contracting?

VFD contracting covers supply of the variable frequency drive, building or modifying the panel, installing power and control cabling, setting the drive's parameters for the motor and application, connecting it to the control system and commissioning it under load.

Drive selection and energy studies come from our VFD consultants. Drives on HVAC plant are usually linked to the BMS. Drives for booster sets are part of our water pumping systems.

A drive straight out of the box will turn a motor. Making it run a pump set efficiently, ramp without water hammer, restart after a power dip and report faults to the control room takes proper setup. For VFD contracting in Dubai we commission each drive on its real load and keep a record of the final parameters.

VFD installation is carried out with attention to what shortens drive life: heat, dust and poor cabling. Variable frequency drive panels are ventilated or cooled for plant-room temperatures, motor cables are screened and correctly earthed, and filters or reactors are fitted where the harmonic assessment calls for them.

We provide VFD supply and commissioning for pumps and AHUs in Dubai, as well as chillers, cooling towers, compressors and conveyors. Drives are integrated with PLC and BMS control as part of our industrial automation contracting service: design, installation, commissioning and support. Sizing and payback studies come from our VFD consultant team.

What's included

Drive supply

Rated for the motor, duty and environment.

VFD panels

New panels or retrofits with bypass where required.

Power and control cabling

Screened motor cables and correct earthing.

Parameter setup

Motor data, ramps, limits and protection configured.

Control integration

Speed control and feedback with PLC or BMS.

Commissioning and service

Load tests, parameter backup and repairs.

When to call us

You do not need a finished brief. If any of these sounds familiar, let's talk.

  • Motors run at fixed speed and you want to cut energy use.
  • A drive has failed and needs replacing quickly.
  • Existing drives trip and nobody has the parameter records.

How we work

Designed, installed, commissioned and supported: one team across all four stages.

  1. Design

    Process study, functional description, panel and network design.

  2. Installation

    Panels, drives, instruments and cabling installed and terminated.

  3. Commissioning

    I/O checks, sequence tests and performance runs on the live process.

  4. Support

    Training, documentation, remote assistance and maintenance after handover.

Where we work

  • Manufacturing plants
  • Water and wastewater
  • Utilities and energy
  • Food and beverage
  • Building plant rooms
  • Oil and gas support facilities

Trusted by teams across Dubai and the UAE

  • Empower Energy Solutions
  • APT
  • J-Walt
  • Nimsmarts Technical Services
  • Taslleeh Engineering Solutions
  • VICC Venco Imtiaz Construction Co
  • Awqaf Dubai
  • Burj Al Yarmouk Industries
  • BurJuman
  • Care 4 Group of Companies
  • Dubai Airports
  • Dubai Metro
  • Extol International
  • Future Gulf Contracting
  • Mohammed Bin Rashid Space Centre
  • Speed House Group of Companies

What clients say

See our Google reviews

Really good experience with Solve Tech Vision. Their MEP calculation work was accurate, and the team was easy to communicate with.

Wamala Brenda

Professional MEP consultants in Dubai. They understood our requirements quickly and provided clear technical support.

Mithun Kumar A

Very professional engineering team. Good communication, practical advice, and smooth service from start to finish.

Amani Ziane

The team was genuinely helpful and responsive. They handled our engineering requirements professionally and made the whole process easy.

Shoaib Alam Mohammed

VFD Contracting: questions, answered

Can you retrofit VFDs to existing pumps and fans?

Yes. We check the motor and cabling, install the drive and commission it with the existing controls.

Do you repair or replace faulty drives?

We diagnose first. Some faults are settings or cooling problems; if the drive itself has failed we replace it and restore the parameters.

Is a bypass needed?

On critical equipment a bypass lets the motor run direct if the drive fails. We advise case by case.

Which drive brands do you supply?

The main industrial brands, chosen for local support and compatibility with your control system.

Do VFDs need special cables?

Yes, for the motor side. Screened, symmetrical VFD cable with proper 360-degree glanding reduces interference and protects motor bearings. Long cable runs may also need output filters, which we check at design stage.

Ready to talk about your project?

Call +971 524064300, or send us your drawings and we will reply with next steps.

Call WhatsApp